7800 Series Gateway Installation Guide

Hide TOC

About this Guide


This guide provides installation, and setup procedures for the 7800 series gateway.

Conventions


Product Term Usage
Terminology Description
7800 series gateway This term is used when a description applies to both a TMG7800 and the TMGIP7800 systems.
7800 series system This term is used when a description applies to a TMG7800-CTRL, TMG7800 Telecom Unit and TMG7800-TMS.
TMGIP7800 system This term is used when a description applies to a TMGIP7800-CTRL, TMGIP7800 Telecom Unit and TMGIP7800-TMS.
7800-TE This term is used when a description applies to TMG7800-TE.
7800-DS3 This term is used when a description applies to the TMG7800-DS3.
7800-CTRL This term is used when a description applies to a TMG7800-CTRL and TMGIP7800-CTRL.
7800-TMS his term is used when a description applies to a TMG7800-TMS and TMGIP7800-TMS.
TMG7800 +1 This term is used when a description applies to a TMG7800 that is selected to provide N+1 protection.
7800 N+1 Patch Panel This term is used to refer to patch panels for TMG7800 systems that have N+1

protection.

Contact Us


If you have comments about this guide or any other TelcoBridges technical documentation, please send an email to marketing.

Introduction




Identifying the 7800 Series Gateway Equipment


The 7800 series gateway is comprised of the following equipment:

  • One or two 7800-CTRL gateway controller(s).
  • One to sixteen 7800 Telecom Unit(s).
  • Based upon the configuration of your 7800 series gateway, the number of 7800-TMS media switches may range from zero to two.
  • If the 7800 series gateway employs N+1 protection, one to two 7800 N+1 patch panels are used to provide protection for the TDM network.
  • If the 7800 series gateway employs 1+1 protection, one to two 1 +1 patch panels are used to provide protection for the TDM network.


Telecom Units




7800-TMS


7800 N+1 Patch Panel



1+1 Patch Panels




RJ48C Patch Panel





Installation Prerequisites


For the installation to proceed without interruption, it is important that you verify you have all necessary materials on hand.


A TMG7800 system can range in size from 2 to 22U in vertical rack space, at full capacity with redundant N+1 patch panels. In addition, if your system is configured to use multiple groups of 1+1 patch panels, the total vertical rack space may exceed 22U.




7800-CTRL


For information about the 7800-CTRL, refer to Dell’s documentation:

http://www.dell.com/support/home/us/en/04/product-support/product/poweredge-r330/manuals


Adequate space for the installation of the 7800-CTRL

You must mount the 7800-CTRL on a 19" equipment rack (customer provided). Your 7800-CTRL is a 1U unit. Plan for an additional 1U space on the equipment rack for a redundant 7800-CTRL.

The depth of the 7800-CTRL is greater than the 16” (406mm) depth of the 7800 series telecom units. It is important to plan for an equipment rack of adequate size.


The dimension of the 7800-CTRL (without bezel and redundant power supply)

  • Height x Width x Depth (mm) 42.8 x 434.0 x 625.0
  • Height x Width x Depth (inch) 1.68 x 17.08" x 24.60"

Adequate power supply and power connections

Each 7800-CTRL requires two power connections to provide for its redundant power supply. To guarantee an uninterrupted supply of electricity, each power connection must be fed by a dedicated power source.


An IP address for the management port

Each 7800-CTRL requires a IP address for the management port. To avoid delays, you should have the IP address, netmask and gateway addresses on hand. Take note that the management port supports DHCP.


Cabling

Three customer supplied Ethernet cables are required for each 7800-CTRL, to connect the 7800-CTRL to the switches.



7800 Series Telcom Units


Adequate space for the installation of each 7800 Series Telecom Unit

You must install each 7800 Series Telecom Unit (1-16 units) on a 19" equipment rack (customer provided). Each 7800 Series Telecom Unit is housed in a 1U chassis.


Adequate power supply and power connections

Each 7800 Series Telecom Unit requires two power connections to provide for its redundant power supply. To guarantee an uninterrupted supply of electricity, each power connection must be fed by a dedicated power source.

7800-TMS


Adequate space for the installation of the 7800-TMS

You will need to mount the 7800-TMS on a 19" equipment rack (customer provided). Your 7800-TMS is a 1U unit. Plan for an additional 1U space on the equipment rack for a redundant 7800-TMS.


Adequate power supply and power connections

Each 7800-TMS requires two power connections to provide for its redundant power supply. To guarantee an uninterrupted supply of electricity, each power connection must be fed by a dedicated power source.

7800 N+1 Patch Panel


Adequate space for the installation of the 7800 N+1 Patch Panel

If your system employs N+1 protection, you will need to mount the 7800 N+1 patch panel on a 19" equipment rack (customer provided). Your 7800 N+1 patch panel is a 1U unit. If your system is using Automatic Protection Switching (APS), plan for an additional 1U space on the equipment rack for a second 7800 N+1 patch panel.


Adequate power supply and power connections

Each 7800 N+1 patch panel requires two power connections to provide for its redundant power supply. To guarantee an uninterrupted supply of electricity, each power connection must be fed by a dedicated power source.



7800 1+1 Patch Panel


Adequate space for the installation of the 7800 1+1 Patch Panel

If your system employs 1+1 protection, you will need to mount one or two 7800 1+1 patch panels on a 19" equipment rack (customer provided). Your 7800 1+1 patch panel is a 1U unit.


Adequate power supply and power connections

Each 7800 1+1 patch panel requires two power connections to provide for its redundant power supply. To guarantee an uninterrupted supply of electricity, each power connection must be fed by a dedicated power source.

7800 RJ48C Patch Panel


Adequate space for the installation of the 7800 RJ48C Patch Panel

In a standalone configuration, you will need to mount one or two 7800 RJ48C patch panels on a 19" equipment rack (customer provided). Your 7800 RJ48C patch panel is a 1U unit.


Adequate power supply and power connections

Each 7800 RJ48C patch panel requires two power connections to provide for its redundant power supply. To guarantee an uninterrupted supply of electricity, each power connection must be fed by a dedicated power source.

Preventing Electrostatic Discharge Damage


Electrostatic discharge (ESD) can damage equipment and impair electrical circuitry. This may occur if electronic printed circuit cards are improperly handled and may cause complete or intermittent failure.





Always follow ESD prevention procedures when removing and replacing modules:
  • Ensure that the equipment is grounded.
  • Wear an ESD-preventive wrist strap and ensure that it makes good contact with your skin. Connect the wrist strap clip to an unpainted surface of the equipment or the grounded equipment rack in order to channel away all ESD voltage safely to ground. To guard against ESD damage and shocks, the wrist strap and cord must be in proper working condition.
  • If no wrist strap is available, and you must work with the equipment, ground yourself by touching a metal part of the chassis.



Recommended Reading


This document is written with the assumption that you have a clear understanding of the installation of the equipment described in this document and you are trained to work with the equipment. If you have any technical questions, TelcoBridges TB Support can be reached at the following numbers, or an email can be sent to: support.


  • Americas & Europe Technical Support Centre (GMT-05:00, Montreal): Telephone: +1-450-655-8993 x131 or x102
  • Asia Technical Support Centre (GMT +08:00, Hong Kong): Telephone: +852-3749-9818
  • 24/7 International Support: Telephone: +1-866-438-4703



Installation Preparations





7800-CTRL Gateway Controllers

In the box, you will find the following items:



7800 Series Telecom Unit


In the box, you will find the following items:

  • One 7800 series unit (TMGIP7800, TMG7800-TE, TMG7800-DS3, or TMG7800-STM1).
  • One set of mounting brackets and screws, used to mount the 7800 series telecom unit to a 19" rack.
  • One Tmedia serial adapter to interface with the serial port of your computer with the RJ-45 port of the 7800 series telecom unit.
  • Three CAT5 Ethernet (blue) straight cables (male-male), 3 meters in length.
  • One Important Notice (two-sided document containing pertinent product serial numbers, and other important information).
  • One Product Warranty.
  • One packing slip.
  • Two AC power cables (optional)


Specifically with the TMG7800-TE unit you will also have:

  • One or two patch panel(s)
  • Two SCSI cables per patch panel.

Not included

  • A 19” equipment rack. The 7800 series telecom unit must be installed on a 19” wide equipment rack.
  • USB-Type B cable. This can be used as an alternative way to connect to the serial port of the telecom unit.



7800-TMS Media Switch


In the 7800-TMS media switch box, you will find the following items:

  • One 7800-TMS unit (TMG7800-TMS or TMGIP7800-TMS).
  • Three CAT5 Ethernet (blue) straight cables (male-male), 3 meters in length.
  • One Tmedia serial adapter to interface with the serial port of your computer with the RJ-45 port of the 7800-TMS.
  • One set of mounting brackets and screws, used to mount the TMG7800-TMS to a 19" rack.
  • One Important Notice (two-sided document containing pertinent product serial numbers, and other important information).
  • One Product Warranty.
  • One packing slip.
  • Two AC power cables (optional)


Not included

  • A 19” equipment rack. The 7800-TMS must be installed on a 19” wide equipment rack.
  • You must order one TelcoBridges CAT7 shielded Ethernet crossover cable, with RJ45 type male-male connectors, for each connection between 7800 Telecom units and a 7800-TMS.
  • If your system features a second 7800-TMS, you must order an additional TelcoBridges CAT7 shielded Ethernet cable, with RJ45 male-male terminations, for each 7800 Telecom Unit.



7800 N+1 Patch Panel


The 7800 N+1 Patch Panel contains the following items:

  • One 7800 N+1 patch panel.
  • Three CAT5 Ethernet (blue) straight cables (male-male), 3 meters in length.
  • One Tmedia serial adapter to interface with the serial port of your computer with the RJ-45 port of the 7800 N+1 patch panel.
  • One set of mounting brackets and screws, used to mount the 7800 N+1 patch panel to a 19" rack.
  • Two AC power cables (optional)
  • One packing slip.
  • One Important Notice (two-sided document containing pertinent product serial numbers, and other important information).
  • One Product Warranty.

Not included

  • Optic fibers (They can be purchased from TelcoBridges).
  • A 19” equipment rack. The 7800 N+1 patch panel must be installed on a 19” wide equipment rack.



7800 1+1 Patch Panels


1+1 patch panels are required for the proper connection of the 7800 series 1+1 system, and are automatically included when a 7800 +1 series unit is ordered. The following table lists various 1+1 patch panels you will receive based upon the type of 7800 series telecom unit ordered for your 7800 series 1+1 system.

1+1 Patch Panels
1+1 Patch Panel (32/T1/E1) Provides connection for up to 32 T1/E1 lines from the network to the 7800-TE and 7800-TE+1.


To connect the 7800-TE-16 and the 7800-TE-32 to their respective +1 units and the network, you will required one 1+1 Patch Panel (32 T1/E1).


To connect the 7800-TE-48 and the 7800-TE-64 to their respective +1 units and the network, you will require two 1+1 Patch Panel (32 T1/E1).


Cables provided: 4 SCSI straight cables per 1+1 Patch Panel (32 T1/E1). Three meters in length. This provides connection for up to 32 lines.

1+1 Patch Panel (DS3) Provides connection for up to 3 DS3 lines from the network to the 7800-DS3 and 7800-DS3+1.


Cables provided (with each 1+1 Patch Panel (DS3)):

  • 4 DS3 cables, each two meters in length, are shipped for each DS3 that is ordered. (4, 8, or 12 cables)
  • 4 RJ48C straight cables (yellow), two meters in length.
1+1 Patch Panel (STM1) Provides connection of 1 STM1 line from the network to the 7800-STM1 and 7800-STM1+1.


Cables provided (with each 1+1 Patch Panel (STM1)):

  • 4 pairs of fiber optic cables, two meters in length.
  • 4 RJ48C straight cables (yellow), two meters in length.



Rack Mounting the 7800 Series Gateway Equipment


The 7800 series equipment is mounted on a customer provided equipment rack using the mounting hardware packaged in each box.

Prerequisites


To rack mount the equipment, you will need:

  • One customer-provided equipment rack, measuring 19” in width and 31.5” in depth. The rack must be solidly anchored to the floor with appropriate support at the top of the racks.
  • Climate controlled room: 0 to +50 Celsius, 0 to 95% non-condensing humidity.



Vertical Placement of the Equipment


The 7800-CTRL and 7800-TMS are each housed in 1U chassis, while 7800 Telecom units are housed in 2U chassis. It is important that you provide for enough room on the equipment rack to allow for the installation of the equipment.


Consider the available space on your equipment rack and the height of one or two 7800-CTRL unit(s), one to sixteen 7800 Telecom unit(s), and from zero to two TMG7800-TMS units. Due to the rear-exhaust heat vents and the efficient heat dissipation design, there is no need to leave any physical vertical space above or below the 7800-CTRL unit(s), 7800 N+1 patch panel(s), 7800 Telecom unit(s), and the 7800-TMS unit(s) on the equipment rack.

Tmedia VoIP Gateway Physical Height
Tmedia Model Number Vertical Height
7800-CTRL 1U (1.68 inches or 42.80 mm)
7800 Telecom Unit 1U (1.75 inches or 44.45 mm)
7800-TMS 1U (1.75 inches or 44.45 mm)
RJ48C Patch Panels 1U (1.75 inches or 44.45 mm)
7800 N+1 Patch Panels 1U (1.75 inches or 44.45 mm)



Installing the 7800 Series Gateway on an Equipment Rack


The 7800-CTRL, 7800 Telecom Unit, and 7800-TMS are mounted on a 19" equipment rack using the angle brackets and screws provided in the box.

7800-CTRL


To install the 7800-CTRL on the equipment rack, refer to either the static or sliding rails installation instructions in the following Dell document:



7800 Telecom Units


  1. Using four metal screws, attach one angle bracket to the front, left-hand side of the 7800 Telecom Unit, when viewed from the front. Do the same for the angle bracket on the right-hand side.
  2. Start mounting equipment beneath the 7800-CTRL, keeping in mind the space required on the equipment rack.
  3. Repeat steps 1 and 2 for each additional 7800 Telecom Unit.
If you are installing TMG7800-TE units you will require one to two patch panels per TMG7800-TE. Mount the patch panels beneath each TMG7800-TE.



7800-TMS


  1. Using four metal screws, attach one angle bracket to the front, left-hand side of the 7800-TMS, when viewed from the front. Do the same for the angle bracket on the right-hand side.
  2. Start mounting equipment beneath the last 7800 Telecom Unit, keeping in mind the space required.
  3. Repeat steps 1 and 2 for a second 7800-TMS.



7800 N+1 Patch Panel


  1. Using four metal screws, attach one angle bracket to the front, left-hand side of the 7800 N+1 patch panel, when viewed from the front. Do the same for the angle bracket on the right-hand side.
  2. Start mounting this equipment beneath the last 7800-TMS, keeping in mind the space required on the equipment rack.
  3. Repeat steps 1 and 2 for a second 7800 N+1 patch panel.



7800 1+1 Patch Panel


  1. Using four metal screws, attach one angle bracket to the front, left-hand side of the 7800 1+1 patch panel, when viewed from the front. Do the same for the angle bracket on the right-hand side.
  2. Start mounting this equipment beneath the last 7800-TMS, keeping in mind the space required on the equipment rack.
  3. If required, repeat steps 1 and 2 for a second 7800 1+1 patch panel.



7800 RJ48C Patch Panel


  1. Using four metal screws, attach one angle bracket to the front, left-hand side of the 7800 RJ48C patch panel, when viewed from the front. Do the same for the angle bracket on the right-hand side.
  2. Start mounting this equipment beneath the last 7800-TMS, keeping in mind the space required on the equipment rack.
  3. If required, repeat steps 1 and 2 for a second 7800 RJ48C patch panel.



Installing the 7800-CTRL




Connecting to the 7800 Series Gateway Management Interface


The 7800-CTRL management interface enables administrators to perform management tasks on a 7800-CTRL.


Prerequisites To communicate with the management interface, you need:

  • Two CAT5 Ethernet cables with RJ45 male-male terminations.
Ethernet cables are not supplied with the 7800-CTRL.


To communicate with the Management Interface:

  1. Connect an RJ45 cable from the 7800-CTRL to a Gigabit Ethernet switch.
  2. Connect an RJ45 cable from the 7800-CTRL to a second Gigabit Ethernet switch.




Connecting to the 7800 Series Control Network


The 7800 Series Control network enables communication between the 7800-CTRL, the 7800 TelecomUnit(s), and the 7800-TMS.


Prerequisites

To connect the 7800-CTRL to the control network, you need:

  • Two CAT5 Ethernet cables with RJ45 male-male terminations.


Connections

The 7800-CTRL is connected to the control network using two CAT5 Ethernet cables.


  1. Connect the ETH0 connector on the 7800-CTRL to the Control network switch one.
  2. Connect the ETH1 connector on the 7800-CTRL to the Control network switch two.




Connecting to the Data Network


The 7800-CTRL feature dual GigE ports for connection to multiple VoIP networks.


The data Ethernet ports can be used for, among other things, SIP signaling, if you purchased the performance option. Your network design will dictate whether you need them. The IP address of the VoIP ports are configured using the Web Portal.


Prerequisites

To connect the 7800-CTRL to the data network using a 1Gb connection, you need:

  • Gigabit layer 2 Ethernet switch. A second one is required to support redundancy of the VoIP interface.
  • CAT5 Ethernet cables with RJ45 male-male terminations for connection to the 1Gb ports.


Connections

The 7800-CTRL is connected to the data network by one or optionally two 1Gb Ethernet network links.




Powering Up


The 7800-CTRL is furnished with two AC or two DC power connections. Only once all other equipment installation work has been completed should the equipment be powered up.


Prerequisites


To power the 7800-CTRL, you need:

  • Two independent AC power sources
  • Two power cables



Connecting to AC Power


The 7800-CTRL is furnished with two AC power supplies.


To connect the 7800-CTRL to AC Power:

  1. Connect the first power connector of the 7800-CTRL to the first power source.
  2. Connect the second power connector of the 7800-CTRL to the second power source.




Installing the 7800 Series Telecom Units




Connecting to the Control Network


The 7800 Series Control network enables communication between the 7800-CTRL, the 7800 Telecom unit(s), the 7800-TMS, and 7800 N+1 patch panel(s).


Prerequisites


To connect the 7800 Telecom unit(s), you need:

  • Two CAT5 Ethernet cables with RJ45 male-male terminations for each 7800 Telecom unit.


Connections


The 7800 Telecom unit(s) are connected to the control network using two CAT5 Ethernet cables.


To connect to the control network:

  1. Connect the ETH0 connector on the 7800 Telecom unit to the control network switch one.
  2. Connect the ETH1 connector on the 7800 Telecom unit to the control network switch two.
  3. Repeat steps 1 and 2 for each additional 7800 Telecom Unit.




Connecting to the VoIP Network(s)


Each 7800 Telecom unit features dual GigE ports for connection to different VoIP networks. This provides an access point to manage VoIP traffic. Should one of the IP networks fail, the 7800 Telecom units will continue to manage VoIP traffic using the alternate network.


The IP address of the VoIP ports can be modified using the web portal.

The 7800 Telecom Units require two (2) gigabit layer 2 Ethernet switches.

Prerequisites


To connect the 7800 Telecom units to the VoIP network, you need:

  • Two gigabit layer 2 Ethernet switches. A second one is required to support redundancy of the VoIP interface.
  • Two CAT5 Ethernet cables with RJ45 male-male terminations.
  • Two IP addresses located on different subnets.


Connections The 7800 Telecom units are connected to the VoIP network through two Ethernet GigE network links.


To connect to the VoIP network:

  1. Connect the VoIP0 connector from each 7800 Telecom unit to the first Ethernet switch.
  2. Connect the VoIP1 connector from each 7800 Telecom unit to the second Ethernet switch.




Connecting to the PSTN


The 7800 Telecom Units feature a variety of interfaces to the PSTN network.


Prerequisites


To connect to the PSTN network, you must comply with the requirements of one of the following 7800 Telecom units:

  • Your TMG7800-TE features SCSI connectors for connection to T1/E1 lines.


Standalone Configuration You will need one RJ48C patch panel for each 32 line grouping of T1/E1 line interfaces with 2 SCSI cables per patch panel (supplied). Each T1/E1 line interfaces requires a RJ48C to connect to the PSTN (not supplied).


1+1 configuration You will require a 1+1 Patch Panel (32 T1/E1) for each 32 line grouping of T1/E1 line interfaces with 4 SCSI cables per patch panel (supplied). Each T1/E1 line interfaces requires a RJ48C to connect to the PSTN (not supplied).

  • Your TMG7800-DS3 features BNC connectors for connection to DS3 lines.

Standalone Configuration You will require two coaxial cables for each DS3 interface.


1+1 Configuration

Your 7800-DS3 and 7800-DS3+1 feature BNC connectors for connection to DS3 lines using a 1+1 patch panel. You will require two coaxial cables for each DS3 interface.

  • Your TMG7800-STM1 features DIN 1.0/2.3 75 Ohm electrical or SMF LC optical connectors.


Standalone Configuration You will require two coaxial cables for each STM-1e interface (Main and APS) or two fiber optic cables for each STM-1 optical interfaces (Main and APS).


1+1 Configuration

The 1+1 patch panel does not support STM-1e interfaces.


Your 7800-STM1 and 7800-STM+1 feature SMF LC optical connectors for connection to STM-1 lines using a 1+1 patch panel.


You will require two fiber optic cables for each STM-1 optical interface (Main and APS).


N +1 Configuration

The N +1 patch panel does not support STM-1e interfaces.


Your 7800-STM1 and 7800-STM+1 feature SMF LC optical connectors for connection to STM-1 lines using an N+1 patch panel. You will require two fiber optic cables for each STM-1 optical interface (Main and APS).

SCSI Interface (T1/E1) for the TMG7800-TE


A TMG7800-TE with 4 SCSI connectors enables the connection to T1/E1 lines. The termination impedance is set at 120 ohms. It is possible to connect an external balun in order to convert to 75 ohms.

All ports may not be active. T1/E1 ports are activated by software license; the number of active ports depends on the licenses purchased.


Patch panels use straight connections. In other words, they do not cross the RX and TX signals. Connections between the patch panels and the TMG7800 require straight cables. The supplied SCSI cables are straight cables. Cables used to connect the network to the patch panel must do the cross connection.



Standalone Configuration


To connect the TMG7800-TE to the PSTN:

  1. Start with SCSI ports 0-15 located at the bottom right. Connect one SCSI cable between this port and RJ48C patch panel number 1, ports 0-15. Connect SCSI ports 16-31 to patch panel number 1, ports 16-31.
  2. Repeat step 1, using lines 32-63 and a second RJ48C patch panel. Connect lines 32-47 to patch panel 2, ports 0-15. Connect lines 48-63 to patch panel 2, ports 16-31.




1+1 Configuration


To connect both the 7800-TE and 7800-TE+1 (SCSI) to the PSTN:

  1. Connect each T1/E1 line from the network section of the 1+1 patch panel to the remote equipment.
  2. Connect SCSI ports 0-15 from the Gateway section at the rear of the 1+1 patch panel to the SCSI ports 0-15 of the 7800-TE.
  3. Connect SCSI ports 16-31 from the Gateway section at the rear of the 1+1 patch panel to the SCSI ports 16-31 of the 7800-TE.
  4. Connect SCSI ports 0-15 from the Gateway 1+1 section at the rear of the 1+1 patch panel to the SCSI ports 0-15 of the 7800-TE+1.
  5. Connect SCSI ports 16-31 from the Gateway 1+1 section at the rear of the 1+1 patch panel to the SCSI ports 16-31 of the 7800-TE+1.
To connect 32 more lines to the 7800-TE and the 7800-TE+1, install another 1+1 patch panel and connect the additional 32 lines to ports 32-63 on each unit.



Dual BNC Interface (DS3) for the TMG7800-DS3


A TMG7800-DS3 with 3 sets of BNC connectors enables the connection to DS3 lines.

All ports may not be active. DS3 ports are activated by software license; the number of active ports depends on the licenses purchased.



Standalone Configuration


To connect the TMG7800-DS3 to the PSTN:

  1. Start with the Dual BNC port pair #0 (right-most). Connect one pair of BNC cables between this port and the DS3 line.
  2. Repeat step 1, using the next available pair of BNC PSTN interface ports.


The TMG7800-DS3 features 2 RJ48C connectors that can be used to synchronize the TDM network (BITS interface) or to carry E1/T1 signaling.



1+1 Configuration


To connect both the 7800-DS3 and 7800-DS3+1 to the PSTN:

  1. Connect each DS3 line from the network section of the 1+1 patch panel to the remote equipment.
  2. Connect each DS3 line from the DS3 connectors labeled Gateway of the 1+1 patch panel to the 7800-DS3.
  3. Connect each DS3 line from the DS3 connectors labeled 1+1 of the 1+1 patch panel to the 7800-DS3+1.

Optional

  • Connect bits port 0 and 1 from the 7800-DS3 to the 1+1 patch panel
  • Connect bits port 0 and 1 from the 7800-DS3+1 to the 1+1 patch panel




OC3/STM-1 Interface for the TMG7800-STM1


This section describes the connection to OC3/STM-1 interfaces using three methods:

  • Standalone (without a patch panel)
  • 1+1 protection (with a 1+1 patch panel)
  • N+1 protection (with an N+1 patch panel)

Refer to the following table for a listing of supported STM-1 interfaces. The default SFP module for OC3/STM1 connection is SMF, intermediate reach, (SFP-OC3-IR1) 1310 nm with LC type connectors.

Make certain that the correct SFP model is ordered. If your installation requires a different model from the one that has been provided, you must replace it.
STM-1 Interfaces
Transceiver Model Description Spec Mode Type Range (Km) Wavelength (NM) Connection
SFP-OC3-IR1 OC3/STM1 Hot Pluggable Single-mode Intermediate reach 15 1310 LC
SFP-STM1E STM1E (Electrical) Hot Pluggable 76 ohms copper Max. 180m 1 NA DIN 1.0/2.3

A TMG7800-STM1, with one main and one backup APS OC3 or STM1 port enables connection to OC3/STM1 lines. The APS port is used for OC3/STM1 redundancy. Switchover occurs automatically based on configurable parameters. It is recommended that APS be used if the installation provides this feature.

The TMG7800-STM1 features 2 RJ48C connectors that can be used to synchronize the TDM network (BITS interface) or to carry E1/T1 signaling.



Standalone Configuration


To connect the TMG7800-STM1 (Optical Interface) to the PSTN:

  1. Connect a fiber optic cable between the Port 0 (Main) port and OC3/STM1 line.
  2. Connect a fiber optic cable between the Port 1 (APS) port and OC3/STM1 line.




1+1 Configuration


To connect both the 78007800-STM1 and 7800-STM +1 (Optical Interface) to the PSTN:

  1. Connect each OC3/STM1 line of the network section of the 1+1 patch panel to the remote equipment.
  2. Connect a fiber optic cable between STM1 of the Gateway section of the 1+1 patch panel and the main port of the 7800-STM1.
  3. Connect a fiber optic cable between APS of the Gateway section of the 1+1 patch panel and the APS port of the 7800-STM1.
  4. Connect a fiber optic cable between STM1 of the Gateway 1+1 section of the 1+1 patch panel and the main port of the 7800-STM1 +1.
  5. Connect a fiber optic cable between APS of the Gateway 1+1 section of the 1+1 patch panel and the APS port of the 7800-STM1 +1.


Optional

  • Connect bits port 0 and 1 from the 7800-STM1 to the 1+1 patch panel.
  • Connect bits port 0 and 1 from the 7800-STM1+1 to the 1+1 patch panel.




N+1 Configuration


The 7800 N+1 patch panels function as the bridge between the provider network and the TMG7800- STM1 gateways. To properly wire your gateways to the 7800 N+1 patch panel(s) to provide N+1 protection, follow these guidelines.

  1. Prepare a diagram that links each Tmedia unit serial number with an N+1 patch panel port and the network provider's STM1. This diagram will help for the web portal configuration later on.
  2. Relate the fiber optic cables from the network provider with each TMG7800-STM1 and use the same port number that is assigned to each TMG7800-STM1. See figure 4.9 on page 36
  3. If Automatic Protection Switching (APS) is used then repeat the EXACT SAME numbering scheme for each APS connection. For example, if a TMG7800-STM1 is assigned port number one on a 7800 N+1 patch panel that is being used for main connections, then the APS connections must also be assigned port number one on a 7800 N+1 patch panel that is being used for APS connections.
  4. Connect the TMG7800+1 unit to the N+1 port of the N+1 patch panel.




Connecting to the TMS Network


You must order one TelcoBridges CAT7 shielded Ethernet crossover cable, with RJ45 type male-male connectors, for each connection between 7800 Telecom units and a 7800-TMS.



Connecting to the TMG7800 Telecom Units


The 7800-TMS enables you to scale your system by interfacing as many as sixteen 7800 Telecom Units with the 7800-TMS Switch network, building a non-blocking system of up to 32,768 channels. A second 7800-TMS provides your system with an active/standby high availability architecture.

Prerequisites


Use TelcoBridges CAT7 shielded Ethernet crossover cable to interconnect the 7800 Telecom Units with the 7800-TMS.

  • Order one TelcoBridges CAT7 shielded Ethernet crossover cable, with RJ45 type male-male connectors, for each connection between 7800 Telecom units and a 7800-TMS.
  • If your system features a second 7800-TMS, you must order an additional TelcoBridges CAT7 shielded Ethernet cable, with RJ45 male-male terminations, for each 7800 Telecom Unit.



Connections


To connect the 7800-TMS: 1. Start with the 7800 Telecom Unit at the topmost position of the equipment rack and connect a TelcoBridges CAT7 shielded Ethernet crossover cable to the TMS0 connector at the rear of the 7800 Telecom Unit. Connect the other end of the same TelcoBridges CAT7 cable to the first port of the first 7800-TMS.

Ensure that the TMS0 port of all the 7800 Telecom units connect to the same 7800-TMS switch.

2. If your system employs a second 7800-TMS, connect a second TelcoBridges CAT7 shielded Ethernet crossover cable to TMS1 at the rear of the TMG7800 Telecom Unit. Connect the other end of the same TelcoBridges CAT7 cable to the first port of a second 7800-TMS.

Ensure that the TMS1 port of all the 7800 Telecom units connect to the same 7800-TMS switch.

3. Repeat steps 1-2 for each 7800 Telecom Unit until they have all been connected to the 7800-TMS.

All telecom units must use the same TMS port number when two 7800-TMS units are available.




Interconnecting Two 7800 Telecom Units


If your 7800 Series gateway has no more that two 7800 Telecom Units, they can be connected to each other without the use of a 7800-TMS switch, with two TelcoBridges CAT7 shielded Ethernet crossover cables. Simply connect the TMS0 ports of each unit together using a TelcoBridges CAT7 shielded cross-over cable, with RJ45 male-male terminations. Do the same for the TMS1 ports of each unit.




Grounding the Equipment Chassis


As a standard safety practice, the chassis of the 7800 Telecom unit must be properly grounded to protect against any contact with an electrical fault condition. It is recommended that the chassis be connected to earth ground. When the 7800 Telecom unit is installed in an equipment rack, connect the ground wire between the ground lug of the Telecom unit and the equipment rack ground bar.


Guidelines

  • Use 10 AWG (minimum) stranded ground wire.
  • Terminate equipment side of ground wire with a #10 ring terminal.
  • Keep the length of the ground wire as short as possible.
  • Do NOT daisy chain the ground between equipment. Use a ground bus bar.
  • Do not over tighten ground lug connections.


To connect the 7800 Telecom unit to ground:

  1. Connect one end of a ground wire to the ground lug of the 7800 Telecom unit.
  2. Connect the other end of the ground wire to a ground bar of the equipment rack. If the 7800 Telecom unit is not installed in an equipment rack, connect the ground wire to earth ground.
  3. Verify that the resistance of the ground path is less than 0.5 ohms.




Powering Up


The 7800 Telecom Units are furnished with two AC or DC power connections. Only once all other equipment installation work has been completed should the 7800 Telecom Unit be powered up.

Connecting to AC Power


Prerequisites To power the 7800 Telecom Unit, you will need:

  • One to two power sources.
  • Two power cables.

The 7800 Telecom Unit AC model is furnished with two AC power connectors.


To connect the 7800 Telecom Unit to AC Power:

  1. Connect an AC power cable between the AC connector of the 7800 Telecom Unit and an AC supply.




Connecting to DC Power


The 7800 series gateway DC model is furnished with two DC power connection ports. In addition, each DC powered unit is supplied with two DC power cables.

Fuse and Cabling Requirements

16 AWG wiring must be used and the 48V supply must be protected with a customer provided 5A 48V fuse.


To connect to DC power:

  1. Connect one wire from the positive terminal of the 7800 series gateway to the return side of DC power source one.
  2. Connect another wire from the negative terminal of the 7800 series gateway to the -48V side of DC power source one.
  3. Connect a ground wire from the ground terminal of the 7800 series gateway to earth ground.
  4. Repeat steps 1-3 for the second power DC power source.




Installing the 7800-TMS




Connecting to the Control Network


The Control network enables the communication between the 7800-CTRL, the 7800 Series Telecom Unit(s), and the 7800-TMS.


Prerequisites

To connect the 7800-TMS, you will need:

  • Two CAT5 Ethernet cables with RJ45 male-male terminations.

Connections The 7800-TMS is connected to the 7800 series control network using two CAT5 Ethernet cables.


To connect to the control network:

  1. Connect the ETH0 connector on the 7800-TMS to Control network switch one.
  2. Connect the ETH1 connector on the 7800-TMS to Control network switch two.
  3. Repeat step 1 and 2 for a second 7800-TMS.




Grounding the Equipment Chassis


As a standard safety practice, the chassis of the 7800 TMS must be properly grounded to protect against any contact with an electrical fault condition. It is recommended that the chassis be connected to earth ground. When the 7800 TMS is installed in an equipment rack, connect the ground wire between the ground lug of the unit and the equipment rack ground bar.


Guidelines

  • Use 10 AWG (minimum) stranded ground wire.
  • Terminate equipment side of ground wire with a #10 ring terminal.
  • Keep the length of the ground wire as short as possible.
  • Do NOT daisy chain the ground between equipment. Use a ground bus bar.
  • Do not over tighten ground lug connections.



7800 TMS


To connect 7800 TMS unit to ground:

  1. Connect one end of a ground wire to the chassis ground lug of the 7800 TMS.
  2. Connect the other end of the ground wire to a ground bar of the equipment rack. If the 7800 TMS is not installed in an equipment rack, connect the ground wire to earth ground.
  3. Verify that the resistance of the ground path is less than 0.5 ohms.




Powering Up


The 7800-TMS is with two (2) AC or two (2) DC power connections. Only once all other equipment installation work has been completed should the 7800-TMS be powered up.


Prerequisites

To power the 7800-TMS, you will need:

  • One to two power sources.
  • Two power cables.



Connecting to AC Power


The 7800 Telecom Unit AC model is furnished with two AC power connectors.


To connect the 7800 Telecom Unit to AC Power:

  • Connect an AC power cable between the AC connector of the 7800-TMS and an AC supply.




Connecting the 7800-TMS to DC Power


The 7800-TMS DC models are furnished with two DC power connection ports.


Fuse and Cabling Requirements

16 AWG wiring must be used and the 48V supply must be protected with a customer provided 5A 48V fuse.


To connect o DC power:

  1. Connect one wire from the positive terminal of the 7800-TMS to the return side of DC power source

one, as shown in figure 5.4 on page 48.

  1. Connect another wire from the negative terminal of the 7800-TMS to the -48V side of DC power

source one.

  1. Connect a ground wire from the ground terminal of the 7800-TMS to earth ground.
  2. Repeat steps 1-3 for the second power DC power source.




TDM System Clock


The 7800 series system must be synchronized with the TDM network in one of several ways: • Synchronized with an incoming trunk • Synchronized with a SONET SDH • Synchronized with a BITS port. If your system features a 7800-TMS and a BITS interface is available, it is recommended that the BITS interface be connected to the BITS port of the 7800- TMS

Installing the 7800 N+1 Patch Panel




Connecting Fiber Optic Cables to the 7800 N+1 Patch Panel


To learn more about the TDM connections to a 7800 N+1 patch panel, See “N+1

Configuration”.



Connecting to the Control Network


The 7800 Series Control network enables communication between the 7800-CTRL, the 7800 Telecom unit(s), the 7800-TMS, and 7800 N+1 patch panel(s).


Prerequisites

To connect the 7800 N+1 patch panel(s) to the control network, you will need:

  • Two CAT5 Ethernet cables with RJ45 male-male terminations for each 7800 N+1 patch panel.


Connections

The 7800 N+1 patch panel(s) are connected to the control network using two CAT5 Ethernet cables.


To connect to the control network:

  1. Connect the ETH0 connector on the 7800 N+1 patch panel to the control network switch one.
  2. Connect the ETH1 connector on the 7800 N+1 patch panel to the control network switch two.
  3. Repeat steps 1 and 2 for an additional 7800 N+1 patch panel.




Grounding the Equipment Chassis


As a standard safety practice, the chassis of 7800 N+1 patch panel must be properly grounded to protect against any contact with an electrical fault condition. It is recommended that the chassis be connected to earth ground. When the 7800 N+1 patch panel is installed in an equipment rack, connect the ground wire between the ground lug of the patch panel and the equipment rack ground bar.


Guidelines

  • Use 10 AWG (minimum) stranded ground wire.
  • Terminate equipment side of ground wire with a #10 ring terminal.
  • Keep the length of the ground wire as short as possible.
  • Do NOT daisy chain the ground between equipment. Use a ground bus bar.
  • Do not over tighten ground lug connections.


To connect to the 7800 N+1 Patch Panel to ground:

  1. Connect one end of a ground wire to the ground lug of the 7800 N+1 Patch Panel.
  2. Connect the other end of the ground wire to a ground bar of the equipment rack. If the 7800 N+1 Patch Panel is not installed in an equipment rack, connect the ground wire to earth ground.
  3. Verify that the resistance of the ground path is less than 0.5 ohms.




Connecting to AC Power


The 7800 N+1 patch panel is furnished with two AC power connections. Only once all other equipment installation work has been completed should the equipment be powered up.


Prerequisites

To power the 7800 N+1 patch panel, you will need:

  • One to two power sources.
  • Two power cables.


To connect the 7800 N+1 Patch Panel to AC Power:

  • Connect an AC power cable between the AC connector of the 7800 N+1 Patch Panel and an AC supply.




Start Up and Verification




Start Up


1. Connect to the web portal of the 7800-CTRL primary unit.


2. Follow the web portal instructions to configure your unit as a primary unit in a new 7800 series system. 3. Before clicking the “yes, it is connected like that already” button, make sure that the physical connections have been properly done. 4. Connect to the web portal of the 7800-CTRL secondary unit. 5. Follow the web portal instructions to configure your unit as a secondary unit in a new 7800 series system. 6. Before clicking the “yes, it is connected like that already” button, verify that the physical connections are properly done.

Verifying the LED Status Indications


When the 7800 series gateway has been powered up, verify the LEDs of each unit to determine that all indications are normal.

7800-CTRL


To determine the operating health of the TMG7800-CTRL, verify the LED statuses at the front and rear of the unit


Refer to the Dell documentation for information that is displayed on unit:

product/poweredge-r330/manuals

7800 Telecom Unit


When the equipment is powered, verify the front panel to determine that the LED indication is normal.

7800 Series Unit Displays
LED Description
Green - Steady Ready
Green - Blinking Starting up or shutting down
Orange - Steady Shut down (stopped)
Red - Blinking Fault condition
An alarm will sound if one of the power supplies is faulty. To stop the alarm, you must remove the faulty power supply.




7800-TMS


Once the 7800-TMS has run successfully through its system boot procedures, the following will be displayed in an alternating fashion.

7800 TMS Displays
Display Order Display
First Screen Toolpack
controlled
from host <serial number>
Second Screen Serial
<Serial number>

IP

<eth0 ip>/<eth1 ip>

When pressing the reset button, the following will appear (it is only possible to restart, no shutdown option available):

Reset?

>Yes

No

  • Select with the function button, the press the reset button again to apply the change.



7800 N+1 Patch Panel


Once the 7800 N+1 Patch Panel has run successfully through its system boot procedures, the following will be displayed.

7800 N+1 Patch Panel LEDs Description
LED Display
Net *Solid Green: Laser received from network.
  • Black: Not configured.
  • Red: Configured but no laser is received.
GW *Black: Configured normal state, or not configured.
  • Blinking yellow: Unit replaced by backup unit.
  • Blinking red: Replaced but no signal is received from the network.
N+1 *Black: N+1 unit is in standby.
  • Blinking green: N+1 unit is active.
  • Blinking red: Replaced but no signal is received from the network.
4 LEDS to the far right *Top left: Green (power on); Red (booting)
  • Bottom left: Green steady (ready); yellow or green blinking (booting); red (boot sequence error)
  • Top right: Unused
  • Bottom right: Black (patch panel OK); red (hardware failure)




Powering Down the Equipment




7800-CTRL


DO NOT TURN OFF the power to the 7800-CTRL unless the Linux host has been properly shut down beforehand. Use the reset button display, or manually use the shutdown command.


Allow enough time for the Linux host to shut down before turning off the power (example. 1 minute). Be aware that the shutdown procedure of the unit is logged and traceable for support and warranty purposes.



Local Method


To power down the 7800-CTRL, refer to the Dell documentation:



Remote Method


To power down, you must connect to the management interface using SSH, and enter:

shutdown -hP now



7800 Telecom Unit


Unplug the power cord from the unit. The unit can be restarted using restart button on the front of the unit.

7800-TMS


Unplug the power cord from the unit. The unit can be restarted using restart button on the front of the unit.

7800 N+1 Patch Panel


Unplug the power cord.

Initial System Configuration




7800 Series Gateway SSH Connection


The 7800 Series Gateway is shipped with the TMG-CONTROL software preinstalled. In order to make changes to the system configuration, you must connect the port, labelled MGMT0, at the front of the 7800 Series Gateway to a terminal.


To access the 7800 Series Gateway, you must use an SSH connection. The password is set at the factory and is indicated on the shipment sheet.




7800 Series Gateway Serial Connection




Connecting to the 7800-CTRL Console


The default IP addresses for the management ports are located in the “Important Notice” sheet received with the shipment. MGMT ports are configured in bonding.

You can connect to the serial port of a 7800-CTRL, using one of the following three methods.


Method 1: Null modem DB9 female-female cable

  • Connect a null modem DB9 female-female cable between the DB9 serial port of your computer and the DB9 serial port of the 7800-CTRL.



Method 2: USB to DB9 adapter

  • Connect the USB connector of the cable to a USB port on your computer and the DB9 male connector of the cable to one end of a null modem DB9 female-female cable. Connect the other end of the null modem DB9 female-female cable to the DB9 serial port of the 7800-CTRL.



Method 3: VGA Monitor, USB Keyboard, and USB Mouse

  • Connect a VGA monitor to the VGA port of the 7800-CTRL. Connect a USB keyboard to an available USB port on the 7800-CTRL. Do the same for a USB mouse.




Configuring the Terminal Emulator Application


Before initiating communication with the management interface, you must first configure a terminal emulator or console application to communicate with the 7800 series system in order to configure initial settings. Available terminal emulation software includes:

  • SecureCRT
  • Putty
  • Minicom


To configure the terminal emulator application: 1. Set the baud rate (bits per second) to 9600 2. Set the data rate to 8 bits 3. Set the parity to None 4. Set the stop bits to 1 5. Set the flow control to None

Changing the 7800 Series Gateway Management Port IP Address


The management port of the 7800 series gateway (MGMT0 and MGMT1) are configured in bonding by default and the values are located on the “Important Notice” sheet.


The values can be modified using the following shell script:


tbchangeip
If you do not have the “Important Notice” sheet, the default IP address and netmask are set as follows:

MGMT0

  • IP address: 172.24.0.2
  • Netmask: 255.255.255.0


MGMT1

  • IP address: 172.24.0.3
  • Netmask: 255.255.255.0



Retrieving 7800 Series Gateway Information


The 7800 series gateway enables you to retrieve system information with the following shell commands:

  • tbinfo (retrieve the 7800 series gateway product type). See TMG:Get_Product_Type, for further information.
  • tbserial (retrieve the 7800 series gateway serial number). See TMG:Get_Serial_Number, for further information.



Changing 7800 Series Gateway Management Port Passwords


Once logged you are logged on to the Tmedia VoIP Gateway, type “passwd”, to change the password being used. The following information will be displayed:

[root@TB003540 ~]# passwd


Changing password for user root.
New UNIX password:
Retype new UNIX password:
passwd: all authentication tokens updated successfully.



Configuring the 7800 Series Gateway Using the Web Portal


Use the Web Portal to configure the 7800 series gateway. Follow the steps described in the Web Portal System Configuration Tutorial Guide, found on the TBWiki:

The Web Portal can be accessed with a Web browser. The default url is: http://[7800-ctrl MGMT0 IP address]:12358

The default login information to access the Web Portal application is:

  • Username: root
  • Password: root



System Backups




Creating a Database Backup


It is important that backups be made of system configuration settings in the event of a system failure. It is recommended that a backup be made once the system has been configured. Backups are performed using the web portal.

Downloading a Database Backup


A backup of system data is stored on the hard drive of the 7800 series gateway. It is important that system backups be downloaded to an external storage device.

Uploading a Database Backup


An external backup of your database can be uploaded to your 7800 series gateway.

Restoring a Database Backup


In the event of a system failure requiring the replacement of a 7800 series gateway, a previously saved backup of system settings can be restored to the new unit.

Wiring Diagrams




RJ48C Wiring Diagram: Crossover and Straight Cables




RJ48 Console Wiring Diagram