The 'Network device name' for transcoding must be trans. To have redundancy, the trans port bonding (using trans0 and trans1 physical ports) needs to be created at initialization time.
For baremetal, the trans port bonding, using trans0 and trans1 physical ports must be bonded at initialization time. You can look here for reference: Initial Configuration (Search for "Bonding")
For virtual machines, the virtual ports trans0 and trans1 are bonded in the Hypervisor layer of the virtual machine (optional) and the tran interface is presented to the guest (the ProSBC).
Hardware Unit - TB002177 is the TSBC-HW-TRANS unit in the below setup.
Network device name
Purpose
Network device role
Network Config
voip0
transcoding port
trans
Tagged 752 (Bonded with voip1)
voip1
transcoding port
trans
Tagged 752 (Bonded with voip0)
eth0
control port
ctrl0
Untagged PVID 750 **
eth1
control port
ctrl1
Untagged PVID 751 **
NOTE: Since the control ports on the device cannot be tagged, this must be done by the network switch. The control ports need to be configure with Link Type: Access