Creating an MTP3 Configuration for STP
| This article applies to: | Product | Version |
| Tmedia | 3.0, 3.2, 3.3 |
Once you have set up the MTP2 layer of your SS7 system, you must create an MTP3 configuration. MTP3 provides message routing between signaling points in an SS7 network.
- Note: When creating an STP configuration (MTP3 routing), we need to add specific options in the configuration.
To create an MTP3 configuration for STP:
1- Select MTP3 from the navigation panel
2- Configure the new MTP3 service:
- Enter a name for the MTP3 configuration
- Make sure the Enabled and SSf Validation boxes are checked
- Select STP as the signaling point type
- Click Create
3- Verify that the "Mtp3Cfg was successfully created" message appears
Path
/configurations/@[configuration_name]/mtp3_stacks/@[mtp3_name]
Parameters (text)
/configurations/@[configuration_name]/mtp3_stacks/@[mtp3_name] enabled = true name = "@[mtp3_name]" signaling_point_type = "SP" /configurations/@[configuration_name]/mtp3_stacks/@[mtp3_name]/advanced_parameters ssf_validation = true transfer_restrict_required = false /configurations/@[configuration_name]/mtp3_stacks/@[mtp3_name]/timers t15_timer = "2 seconds" t16_timer = "1400 milliseconds" t18_timer = "11 seconds" t19_timer = "67 seconds" t21_timer = "63 seconds" t26_timer = "12 seconds"
Parameters (json)
{
"advanced_parameters" : {
"ssf_validation" : true,
"transfer_restrict_required" : false
},
"enabled" : true,
"name" : "@[mtp3_name]",
"signaling_point_type" : "SP",
"timers" : {
"t15_timer" : "2 seconds",
"t16_timer" : "1400 milliseconds",
"t18_timer" : "11 seconds",
"t19_timer" : "67 seconds",
"t21_timer" : "63 seconds",
"t26_timer" : "12 seconds"
}
}
List of Parameters
Timers
Advanced Parameters