Actions

Creating an OC3 Line Interface

Revision as of 11:37, 22 February 2023 by Allyntree (talk | contribs)
This article applies to: Product Version
Tmedia 2.9, 2.10, 3.0, 3.2

Line interface is a generic term for TDM physical interfaces. TelcoBridges products support 3 types of physical interfaces:


To create an OC3 line interface(s):

1- Select TDM Line Interfaces from the navigation panel.


2- To create a single OC3 line interface, click Create New Line Interface.


This configures the MAIN interface on the rear of the TMG unit.

3- Enter values for the line interface.

  • Enter a name for the interface
  • Set type OC3 for the interface
  • Set local index 0 for the line (this is the only choice for OC3)
  • Select Payload Type STS3 (this is the only choice for OC3)
  • Select Use APS Protection to use the redundant optical interface, named APS on the rear of the device.
  • Click Create



4- Verify that the "Line interface was successfully created" message is displayed


Path


/configurations/@[configuration_name]/hardware_units/@[hardware_name]/tdm_line_interfaces/@[line_interface_name]

Parameters (text)

/configurations/@[configuration_name]/hardware_units/@[hardware_name]/tdm_line_interfaces/@[line_interface_name]
local_index   = 0
name          = "@[line_interface_name]"
type          = "T1"

/configurations/@[configuration_name]/hardware_units/@[hardware_name]/tdm_line_interfaces/@[line_interface_name]/state
loopback_type = "None"
tx_state      = "TX on"

/configurations/@[configuration_name]/hardware_units/@[hardware_name]/tdm_line_interfaces/@[line_interface_name]/t1_parameters
encoding     = "B8ZS"
length       = "Short"
signal_level = "2"


Parameters (json)


{
  "local_index" : 0,
  "name" : "LI_T1_00",
  "state" : {
    "loopback_type" : "None",
    "tx_state" : "TX on"
  },
  "t1_parameters" : {
    "encoding" : "B8ZS",
    "length" : "Short",
    "signal_level" : "2"
  },
  "type" : "T1",
  "line_services" : {
  }
}


List of Parameters


Other links

Automatic Protection Switching