This procedure does not require system downtime.

Start with the following steps: Prepare for replacement

The replacement of a Secondary TMG3200 is comprised of following steps:

Removing the Defective Unit

  • Shutdown the Secondary TMG3200
  • Disconnect from the 1+1 patch panel
  • Disconnect from the VoIP network
  • Disconnect from the Management network
  • Remove the Secondary TMG3200 from the equipment rack

Installing the Replacement Unit

Refer to TMG3200 Installation guide

  • Rack-mount the Replacement Unit
  • Connect to the Management Interface
  • Connect to the VoIP Network
  • Connect to the 1+1 patch panel
  • Connect the ETH0 and ETH1 port to the secondary unit

Starting Up the TMG3200

Configuring the replacement unit

The configuration database will replicate itself from the primary unit and will be ready to process calls a few minutes later.