Toolpack:Adding a Transcoding Unit A: Difference between revisions
No edit summary |
No edit summary |
||
| Line 8: | Line 8: | ||
|- | |- | ||
|SBC | |SBC | ||
|3. | |3.1, 3.3 | ||
|} | |} | ||
Latest revision as of 12:36, 22 June 2024
| This article applies to: | Product | Version |
| SBC | 3.1, 3.3 |
To add a transcoding unit:
1- Click Hardware Units in the navigation panel
2- Click Create New Unit, to add a new hardware device
3- Enter information for the following parameters:
- Enter a name for the hardware device
- Enter the serial number of the new hardware device (filling in the Serial Number field will cause auto-completion of the field to occur).
- Select TDM and/or IP from the Type field.
- Enter the location in which the hardware device is installed.
- Enter a meaningful description about the use or purpose of the hardware device.
- Select Enabled from the Target State field.
- Select the type of TDM lines that the hardware device will support.
- Leave the Is N+1 Backup field empty.
- Provide the amount of time in seconds, that the system will wait for calls to complete before shutting down for an upgrade.
- Click Create
4- Verify that the Unit was successfully created message appears, and that the newly added hardware device appears in the Hardware List.
List of Parameters
- Name
- Serial Number
- Type
- Location
- Description
- Target State
- TDM Lines Type
- Is N+1 Backup
- Graceful Upgrade Timeout
- Enable management port redundancy
- Enable HTTP access
- Enable Telnet access
- Enable V.34 FAX
- Enable V.152 VBD
- ISDN primary CPU load
- Load CAS on secondary CPU
- Load ISUP on secondary CPU
- Load M2PA on secondary CPU
- Load M2UA on secondary CPU
- Load M3UA on secondary CPU
- Load SIP on secondary CPU
- Load IUA on secondary CPU
- Load LAPD on secondary CPU
- Increase SIP Stack Allowed RAM
- SIP Dynamic memory size
- SIP Event memory size
- SIP Signal memory size
- SIP Signal pool sizes
- Reduced Timer
- Congestion
- Critical Congestion
- TDM Companding
- VOIP Codec Mode
- Fixed density for G711 (20 ms packets)
- Fixed density for G711 (10 ms packets)
- Fixed density for G711 (5 ms packets)
- Fixed density for G726 (20 ms packets)
- Fixed density for G726 (10 ms packets)
- Fixed density for G729A
- Fixed density for G723
- Fixed density for G728
- Fixed density for G729EG 8 Kbps
- Fixed density for G729EG 11.8 Kbps
- Fixed density for AMR
- Fixed density for EVRC
- Fixed density for QCELP8
- Fixed density for QCELP13
- Fixed density for SMV
- Fixed density for EFR
- Fixed density for T38
- Fixed density for ECHO high-latency
- Fixed density for ECHO medium-latency
- Fixed density for ECHO low-latency
- Fixed density for FR
- Fixed density for ILBC 13 Kbps
- Fixed density for ILBC 15 Kbps
- Fixed density for G722.2
- Maximum SS7 calls per second
- Maximum SS7 call burst
- Maximum ISDN calls per second
- Maximum ISDN call burst
- Maximum CAS calls per second
- Maximum CAS call burst
- Maximum SIP calls per second
- Maximum SIP call burst
- Maximum total calls per second
- Maximum total call burst