=== '''''Applies to version(s): v3.0, v3.1''''' ===
{{DISPLAYTITLE:Configuring an IP Port Range}}
{{DISPLAYTITLE:Configuring an IP Port Range}}
{| class="wikitable"
|-
|rowspan="2"|This article applies to:
|'''Product'''
|'''Version'''
|-
|SBC
|3.0, 3.1
|}


An IP port range is automatically created for an IP interface carrying the SIP service. The minimum and maximum values for the port range can be modified. By default, Toolpack uses ports from 20,000 to 40,000 for an IP interface.
An IP port range is automatically created for an IP interface carrying the SIP service. The minimum and maximum values for the port range can be modified. By default, Toolpack uses ports from 20,000 to 40,000 for an IP interface.

Revision as of 09:25, 15 December 2020


This article applies to: Product Version
SBC 3.0, 3.1

An IP port range is automatically created for an IP interface carrying the SIP service. The minimum and maximum values for the port range can be modified. By default, Toolpack uses ports from 20,000 to 40,000 for an IP interface.



To modify an RTP port range

1. Select IP Interfaces from the navigation panel:



2. Click the RTP Port Ranges tab:

  • Select an IP Port Range from the RTP Port Ranges list.


3. Configure the range of ports:

  • Enter a minimum port number for the port range
  • Enter a maximum port number for the port range
  • Click Create


List of Parameters