Revision as of 09:59, 5 October 2018

Applies to version(s): v2.9, v2.10

The last step to the H.248 configuration is to assign timeslots to the TDM interfaces that are associated with the H.248 configuration.


1- Click H.248 in the naviagtion panel.


2- Select the line service you wish to configure, in the H.248 configuration window

(NOTE: A timeslot mask can be applied to all line services at once by selecting Timeslot mask for all line services instead)


3- Select timeslots:

  • Add the desired timeslots by checking individual boxes, or simply select all timeslots by clicking Select all
  • Click Save


4- Verify that the "h248_fix_term_cfg was successfully updated" message appears


Path