Actions

MTP2:Specification: Difference between revisions

(initial content)
(added variants for MTP3 and ISUP from SS7 guide)
Line 9: Line 9:




MTP2 can also support different protocol variants:
 
The following messages may be received or transmitted by MTP2 across the line interfaces / line services:
*Message Signal Unit (MSU)
*Link Status Signal Unit (LSSU)
*Fill-In Signal Unit (FISU)
 
 
== Variants ==
The following protocol variants are supported:
 
 
'''MTP2'''
*ITU (< ITU BLUE > used for ITU88)
*ITU (< ITU BLUE > used for ITU88)
*ITU92( < ITU WHITE > used for ITU92, ITU97, Q767, SINGAPORE and CHINA)
*ITU92( < ITU WHITE > used for ITU92, ITU97, Q767, SINGAPORE and CHINA)
Line 16: Line 27:




The following messages may be received or transmitted by MTP2 across the Trunk controller:
'''MTP3'''
*Message Signal Unit (MSU)
*ITU = (88, 92, 97, Q767 and SINGAPORE)
*Link Status Signal Unit (LSSU)
*CHINA
*Fill-In Signal Unit (FISU)
*ANSI = (88 and 92)
*ANSI 96 = (96 and TELCORDIA)
 
 
'''ISUP'''
*ITU = (88 and 92)
*ITU 97
*SINGAPORE
*ANSI 88
*ANSI 92
*ANSI 95
*TELCORDIA 97
 
 


[[Category:Needs revising]]
[[Category:Needs revising]]

Revision as of 17:04, 14 August 2009

TelcoBridges' implementation of the MTP2 software conforms to the following standards:

  • TI.111.3 SS7 Signaling Data Link (MTP Level 2), ANSI 1992.
  • Q.701 SS7 (MTP), CCITT 1992.
  • Q.703 SS7 Signaling Data Link, CCITT 1992.
  • Q.781 MTP Level 2 Test Specification, CCITT.
  • JT-Q.703 MTP Signaling Link, TTC recommendation.
  • NTT - Q.703 MTP Specifications, NTT recommendation.


The following messages may be received or transmitted by MTP2 across the line interfaces / line services:

  • Message Signal Unit (MSU)
  • Link Status Signal Unit (LSSU)
  • Fill-In Signal Unit (FISU)


Variants

The following protocol variants are supported:


MTP2

  • ITU (< ITU BLUE > used for ITU88)
  • ITU92( < ITU WHITE > used for ITU92, ITU97, Q767, SINGAPORE and CHINA)
  • ANSI88 (used for ANSI88)
  • ANSI92 (used for ANSI92, ANSI96 and TELCORDIA)


MTP3

  • ITU = (88, 92, 97, Q767 and SINGAPORE)
  • CHINA
  • ANSI = (88 and 92)
  • ANSI 96 = (96 and TELCORDIA)


ISUP

  • ITU = (88 and 92)
  • ITU 97
  • SINGAPORE
  • ANSI 88
  • ANSI 92
  • ANSI 95
  • TELCORDIA 97