Continuity tests are used to make sure that the SS7 ISUP interface circuit groups (CIC) are aligned with the physical links (E1/T1) properly.
{{DISPLAYTITLE:Continuity Testing Call Flow (CCR/COT)}}
 
{| class="wikitable"
|-
|rowspan="2"|This article applies to:
|'''Product'''
|'''Version'''
|-
|Tmedia
|2.7
|}
 
Continuity tests are used to test the speech or transmission path of SS7 circuits. It also ensures that the SS7 ISUP interface circuits (CIC) are aligned with the same physical links (E1/T1) on both ends.
Toolpack version 2.7 allows users of the TMG to do ISUP Continuity Testing via 3 methods by CIC Group or individual CIC:
Toolpack version 2.7 allows users of the TMG to do ISUP Continuity Testing via 3 methods by CIC Group or individual CIC:


== Incoming Continuity testing outside a call ==
== Incoming Continuity Testing Outside a Call ==
This circuit testing occurs when one of the nodes wants to validate a currently idle circuit.  
This circuit testing occurs when one of the nodes wants to validate a currently idle circuit. It is recommended that the switch first blocks the circuit to prevent calls from using the circuit during the testing.
It is recommended that the switch first blocks the circuit to prevent calls to use the circuit during the testing.


For ITU:
For ITU:
<pre>
<pre>
Peer SP                                       TMG
        Peer SP                     TMG
 
          |                          |
IAM           - - - - - - - - - - ->  
           |---------- CCR ---------->|       
 
          |                          | (timeslot loopback)
 
          |---------- Tone ----------\
Check tone    - - - - - - - - - - -|
          |<-------------------------/
 
          |                          |
                - - - - - - - - - -
           |---------- REL ---------->|
 
          |<--------- RLC -----------|
REL           - - - - - - - - - - ->
 
              < -- - - - - - - - - -         RLC
</pre>
</pre>


For ANSI:
For ANSI:
<pre>
<pre>
Peer SP                                       TMG
        Peer SP                     TMG
          |                          |
          |---------- CCR ---------->|
          |                          | (timeslot loopback)
          |<--------- LPA -----------|
          |                          |
          |---------- Tone ----------\
          |<-------------------------/
          |                          |
          |---------- REL ---------->|
          |<--------- RLC -----------|
</pre>


CCR            - - - - - - - - - - ->
== Incoming Continuity Testing Within A Call ==
This circuit testing occurs when the forward side (originating side) sets the ‘continuity test required’ field of the ‘nature of connection indicators’ IE into the IAM message.


              < -- - - - - - - - - -         LPA
Successful continuity check:
 
<pre>
Check tone    - - - - - - - - - - -|
        Peer SP                    TMG
 
          |                          |
                - - - - - - - - - -
          |---------- IAM ---------->| 'continuity test required'
 
          |                          |
REL           - - - - - - - - - - ->
          |                          | (timeslot loopback)
 
          |---------- Tone ----------\
              < -- - - - - - - - - -         RLC
          |<-------------------------/
          |                          |
          |---------- COT ---------->| continuity check successful
          .                          .
          .                          .
          .                          .
           |---------- REL ---------->|
          |<--------- RLC -----------|
</pre>


Failed continuity check with retry from Peer SP:
<pre>
        Peer SP                    TMG
          |                          |
          |---------- IAM ---------->| 'continuity test required'
          |                          |
          |                          | (timeslot loopback)
          |---------- Tone ----------\
          |<-------------------------/
          |                          |
          |---------- COT ---------->| continuity check failed
          |                          |
    Retry |---------- CCR ---------->|       
          |                          | (timeslot loopback)
          |---------- Tone ----------\
          |<-------------------------/
          |                          |
          |---------- COT ---------->| continuity check successful
          .                          .
          .                          .
          .                          .
          |---------- REL ---------->|
          |<--------- RLC -----------|
</pre>
</pre>


== Incoming Continuity testing within a call ==
== Outgoing Continuity Testing ==
This circuit testing occurs when the forward side (originating side) sets the ‘continuity test required’ field of the ‘nature of connection indicators’ IE into the IAM message.
Users of the Tmedia unit can easily generate, out of call, SS7 ISUP Continuity Tests using the web portal.


Peer SP                                       TMG
<pre>
IAM          - - - - - - - - - - ->
        Peer SP                     TMG
Check tone    - - - - - - - - - - -|
          |                          |
              - - - - - - - - - - -
          |<--------- CCR ---------- |       
COT (successful) - - - - - - - - -->
(timeslot  |                          |
            <- - - - - - - - - - -           ACM
loopback) |                          |
              - - - - - - - - - - -            Ringing tone
          /---------- Tone ----------|
            <- - - - - - - - - - -           ANM
          \------------------------->| ccr success or fail
Connectivity - - - - - - - - - -          Connectivity
           |                          |
REL          - - - - - - - - - - ->
          |<--------- REL -----------|
            <- - - - - - - - - - - RLC
          |---------- RLC ---------->|
</pre>   


== Outgoing COT testing ==
== Configuration ==
*[[Outgoing COT testing|Web Portal v2.7: Outgoing Continuity Testing]]


Peer SP                                        TMG
== External Sources  ==
            < - - - - - - - - - - -            CCR
*[ftp://109.167.129.114/doc/ITU-T/Q/Q0784e.pdf Q.784-Isup Basic Call Test Specification]
            |- - - - - - - - - - -            Check tone
              - - - - - - - - - -
            < - - - - - - - - - - -            REL
RLC          -- - - - - - - - - - ->   
   
== Configuration ==
*[[Outgoing COT testing|Web Portal v2.7: Outgoing COT testing]]

Latest revision as of 10:26, 12 September 2022


This article applies to: Product Version
Tmedia 2.7

Continuity tests are used to test the speech or transmission path of SS7 circuits. It also ensures that the SS7 ISUP interface circuits (CIC) are aligned with the same physical links (E1/T1) on both ends. Toolpack version 2.7 allows users of the TMG to do ISUP Continuity Testing via 3 methods by CIC Group or individual CIC:

Incoming Continuity Testing Outside a Call

This circuit testing occurs when one of the nodes wants to validate a currently idle circuit. It is recommended that the switch first blocks the circuit to prevent calls from using the circuit during the testing.

For ITU:

         Peer SP                     TMG
           |                          |
           |---------- CCR ---------->|        
           |                          | (timeslot loopback)
           |---------- Tone ----------\
           |<-------------------------/
           |                          |
           |---------- REL ---------->|
           |<--------- RLC -----------|

For ANSI:

         Peer SP                     TMG
           |                          |
           |---------- CCR ---------->|
           |                          | (timeslot loopback)
           |<--------- LPA -----------|
           |                          | 
           |---------- Tone ----------\
           |<-------------------------/
           |                          |
           |---------- REL ---------->|
           |<--------- RLC -----------|

Incoming Continuity Testing Within A Call

This circuit testing occurs when the forward side (originating side) sets the ‘continuity test required’ field of the ‘nature of connection indicators’ IE into the IAM message.

Successful continuity check:

         Peer SP                     TMG
           |                          |
           |---------- IAM ---------->| 'continuity test required'
           |                          |
           |                          | (timeslot loopback)
           |---------- Tone ----------\
           |<-------------------------/
           |                          |
           |---------- COT ---------->| continuity check successful
           .                          .
           .                          . 
           .                          .
           |---------- REL ---------->|
           |<--------- RLC -----------|

Failed continuity check with retry from Peer SP:

         Peer SP                     TMG
           |                          |
           |---------- IAM ---------->| 'continuity test required'
           |                          |
           |                          | (timeslot loopback)
           |---------- Tone ----------\
           |<-------------------------/
           |                          |
           |---------- COT ---------->| continuity check failed
           |                          |
     Retry |---------- CCR ---------->|        
           |                          | (timeslot loopback)
           |---------- Tone ----------\
           |<-------------------------/
           |                          |
           |---------- COT ---------->| continuity check successful
           .                          .
           .                          .
           .                          .
           |---------- REL ---------->|
           |<--------- RLC -----------|

Outgoing Continuity Testing

Users of the Tmedia unit can easily generate, out of call, SS7 ISUP Continuity Tests using the web portal.

         Peer SP                     TMG
           |                          |
           |<--------- CCR ---------- |        
(timeslot  |                          |
 loopback) |                          |
           /---------- Tone ----------|
           \------------------------->| ccr success or fail
           |                          |
           |<--------- REL -----------|
           |---------- RLC ---------->|

Configuration