Actions

Creating a Line Interface

Revision as of 16:21, 24 November 2020 by Allyntree (talk | contribs)
(diff) ← Older revision | Latest revision (diff) | Newer revision → (diff)
This article applies to: Product Version
Tmedia 2.9, 2.10, 3.0, 3.2

Line interface is a generic term for TDM physical interfaces. TelcoBridges products support 3 types of physical interfaces:


To create line interface(s):

1- Select TDM Line Interfaces from the navigation panel

CreateLineInterface 0 A.png


2- You can create one line interface at a time or multiple line interfaces in a single pass.

2a- To create a single line interface, click Create New Line Interface.

CreateLineInterface 1 A.png


2b- To create a range of line interfaces, click Create Multiple Line Interfaces.

CreateMultipleLineInterface 0 A.png


3- Enter values for the line interface.

3a- Single line interface

  • Enter a name for the interface
  • Set a type for the interface
  • Set a local index for the line
  • Select a length and an encoding scheme
  • Click Create

CreateLineInterface 2 A.png


3b-Multiple line interfaces

  • Set a type for the interface
  • Enter a name for the range of interfaces. (In this example 'SeriesA' is prefixed to the name)
  • Enter the number of line interfaces you wish to create.
  • Set an index for the first line.
  • Select a length and an encoding scheme
  • Click Create

CreateMultipleLineInterface 1 A.png


4- Verify that the "Line interface was successfully created" message is displayed

CreateLineInterface 3 A.png


Path


/configurations/@[configuration_name]/hardware_units/@[hardware_name]/tdm_line_interfaces/@[line_interface_name]

Parameters (text)

/configurations/@[configuration_name]/hardware_units/@[hardware_name]/tdm_line_interfaces/@[line_interface_name]
local_index   = 0
name          = "@[line_interface_name]"
type          = "T1"

/configurations/@[configuration_name]/hardware_units/@[hardware_name]/tdm_line_interfaces/@[line_interface_name]/state
loopback_type = "None"
tx_state      = "TX on"

/configurations/@[configuration_name]/hardware_units/@[hardware_name]/tdm_line_interfaces/@[line_interface_name]/t1_parameters
encoding     = "B8ZS"
length       = "Short"
signal_level = "2"


Parameters (json)


{
  "local_index" : 0,
  "name" : "LI_T1_00",
  "state" : {
    "loopback_type" : "None",
    "tx_state" : "TX on"
  },
  "t1_parameters" : {
    "encoding" : "B8ZS",
    "length" : "Short",
    "signal_level" : "2"
  },
  "type" : "T1",
  "line_services" : {
  }
}


List of Parameters

Advanced Parameters